Model FD
Fire Rated Access Panel
Masonry, Tile, and Drywall Surfaces
Model FD access panels feature a hinge door panel and provide a convenient and economical means to obtain access to components installed behind vertical walls or partitions, with fire resistance ratings up to 2 hours. In horizontal combustible ceiling membranes of floor-ceiling or roof-ceiling assemblies, they feature fire resistance ratings up to, and including, 1 hour. In horizontal non combustible ceiling membranes of floor-ceiling and roof-ceiling assemblies, the panels have fire resistance ratings up tom and including, 3 hours.
Standard Construction
Frame: 16 ga. (1.6) steel with white baked enamel prime coat finish - 1" (25) flange.
Door Panel: 20 ga. (1.0) steel with white baked enamel prime coat finish.
Hinge: Concealed hinge.
Latches: Universal latch mechanism - convertible between turning and key lock type.
Minimum Size: See table on product sheet.
Maximum Size: See table on product sheet.
Ratings
UL 10B Fire Resistance Rating: 1-1/2 hiur (vertical)
ULC-S104 Fire Resistance Rating: 2 hour (vertical)
ASTM E119 Fire Resistance Rating: 3 hour (horizontal, for use in 1, 2 or 3 hour rated non-combustible assemblies)
ASTM E119 Fire Resistance Rating: 1 hour (horizontal, for use in 1 hour rated combustible assemblies)